John Preston Easter Holidays 3rd-7th April. Please note any orders placed during this time will not be processed until we reopen 8th April. 

Optima Turn Bilateral Turning Air Mattress

Brand:
Product Code:
DPRO-TURN

Optima Turn offers enhanced pressure relief by 30° of Bilateral Turning. Bilateral turning can significantly reduce interface pressure on patients’ body whilst i... read more

  • Buy 5 for £2,973.12 £2,477.60 each and save 5%
  • Buy 10 for £2,816.64 £2,347.20 each and save 10%
Description

OptimaTurn offers enhanced pressure relief by 30° of Bilateral Turning. Bilateral turning can significantly reduce interface pressure on patients’ body whilst increase capillary circulation. 30° of turning not only complies with clinical guidelines but also provides optimal comfort.

Key features

  • Turning, Alternating and Continuous Low Pressure modes to tailor to individual pressure care plans
  • The unique setting for lateral turning therapy with alternating helps on skin reperfusion by the moderate pressure from each inflation cycle which improves body circulation and skin integrity
  • The side bolsters reduce the risk of entrapment and accidental falling out of bed, also support patient´s arms while in turning therapy.
  • Single air-cell deflation floats the vulnerable heels with zero pressure
  • Suitable for patients in medium to high risk of pressure injuries
  • Up to 30° of bilateral turning therapy to assist patient repositioning and enhance pressure relief
  • 3-in-1 therapy available for individual healthcare plans with effortless patient repositioning
  • Designed for caregivers to save time and resources while maintaining quality care to patients

Pump Specification

  • Dimensions 1 x 16.5 x 26.0 cm
  • Weight                5 kg / 9.9 lbs
  • Case Material Flame Retardent ABS
  • Supply Voltage AC 230V, 50Hz
  • Operating Cycle Time 10, 15, 20, 25 min.
  • Dwell Time 10, 20, 30, 60 min.

Mattress Specification

  • Dimensions 200 x 90 x 13 cm, side bolster 25 cm
  • Cell Height 13 cm cells with two turning cells underneath from the 4th to 12th air cells
  • Weight 4 kg / 25 lbs
  • Cover Material 4-way stretch PU / Polyester cover with welded seams
  • Cell Material TPU
  • Maximum User Weight 180 kg / 397 lbs
  • CPR Knob 1 Piece
  • Flame Retardant Standards EN 597-1 & EN 597-2
FAQs

What are the advantages of using Optima Turn?

  1. Save caregiver's time.
  2. Relieve pressure on the hips, sacrum, greater trochanters and heels.
  3. Provide comfort and stability.
  4. Reduce caregivers' exposure to potential harm from intensive patient handlings, such as lifting and resituating patients.
  5. Help reposition patients and increase their mobility.
  6. Customize pressure settings based on the patient's needs.
  7. Continue pressure relief care during transports and events where immediate power is unavailable with battery backup option.
  8. Promote active recovery with inflated seating which provides support and stability and prevents patients from bottoming out.
  9. Quiet operation and automatic turning reduce caregiver interruption to patients sleep patterns.

When the patients are in turn, won't they risk falling off the bed?

The side bolsters protect patients from pressing directly against the side railing and sliding off the mattress. The firmness of these air cells also provides additional comfort for the patient's side when in turn.

How does Optima Turn increase comfort when patients are turned on their sides?

Optima Turn's mattress provides continuous alternating pressure relief, and the side bolsters protect patients from pressing against the railings while providing comfort. In addition, individual deflatable air cells allow caregivers to customize heel relief care. For more posture support, Turn minimises the caregivers' labour in lifting the patient to place foam or pillows as needed quickly.
 

Optima Turn suits which types of patients?

  • Unconscious
  • Bedbound and immobilised
  • Medium to high risk of pressure injures, especially on the scapulae (back shoulder area) and greater trochanters (hip side area)

Optima Turn suits what type of settings?

ICU, GICU, NICU, Neurosurgery and Neurology, and long-term care facilities.

After powering on Optima Turn, what pressure setting will it be set to?

After powering on Optima Turn, the air cells will automatically inflate to their maximum firmness. Once the inflation process is complete, the caregiver can choose between continuous low pressure or alternating pressure modes based on the patient's needs. The pump will automatically switch to the alternating pressure mode if a mode is not selected within the first 10 minutes after the initial inflation process.

How long does it take to change between the left and right turns?

It takes 3-5 minutes to change from left to right turn and vice versa. The patient's BMI (body mass index) and body contour will influence turning duration, with heavier patients taking longer to change between turns. The dwell time starts counting when the turn reaches the selected degrees immediately.

Can the alternating pressure mode be deactivated when the patient is in turn?

No. In turn, the alternating pressure mode is part of the default mode and cannot be deactivated.

What materials are the air cells made from?

All air cells are made from Thermoplastic Polyurethanes (TPU). It is highly resistant to breaking down when in contact with water (hydrolysis), soft to touch, and minimises friction and noise during patient movements.

What does it mean when air cells have cell-in-cell? What are their benefits?

Cell-in-cell design refers to encapsulating a firm air cell within a larger outer cell, doubling the effect of firmness and stability for patients. Wellell’s Optima Series, including Prone, uses air cells with the cell-in-cell design in the sacrum area to improve patient support and comfort during sitting positions and when patients leave and enter the bed.
Technical

Pump Specification

  • Dimensions 1 x 16.5 x 26.0 cm
  • Weight                5 kg / 9.9 lbs
  • Case Material Flame Retardent ABS
  • Supply Voltage AC 230V, 50Hz
  • Operating Cycle Time 10, 15, 20, 25 min.
  • Dwell Time 10, 20, 30, 60 min.

Mattress Specification

  • Dimensions 200 x 90 x 13 cm, side bolster 25 cm
  • Cell Height 13 cm cells with two turning cells underneath from the 4th to 12th air cells
  • Weight 4 kg / 25 lbs
  • Cover Material 4-way stretch PU / Polyester cover with welded seams
  • Cell Material TPU
  • Maximum User Weight 180 kg / 397 lbs
  • CPR Knob 1 Piece
  • Flame Retardant Standards EN 597-1 & EN 597-2
Reviews
Write Your Own Review
You're reviewing: Optima Turn Bilateral Turning Air Mattress
loader
Loading...

You submitted your review for moderation.

Downloads
Contact Us

Previous questions

No Questions Found.
Related Products
Loading...